When it comes to home safety systems, there's significant confusion between fire detectors, smoke alarms, and carbon monoxide (CO) detectors. Many people assume these devices are interchangeable, but this misunderstanding could have dangerous consequences.

Critical Safety Information: Standard fire detectors and smoke alarms cannot detect carbon monoxide gas. You need dedicated CO detectors or combination units to protect against this invisible threat.

Understanding the Different Detection Technologies

Device Type What It Detects Detection Method Alarm Purpose
Smoke Detector Smoke particles from fires Ionization or photoelectric sensors Fire warning
Heat Detector Rapid temperature rise Thermistor or fusible alloy Fire warning
Carbon Monoxide Detector CO gas molecules Electrochemical, biomimetic, or metal oxide semiconductor Poisoning warning

Why Fire Detectors Can't Detect CO

Fire detectors and CO detectors serve fundamentally different purposes:

  • Different threats: Fire detectors respond to physical signs of fire (smoke, heat), while CO detectors sense a specific gas
  • Different sensor technologies: The sensors in smoke detectors have no way to identify CO molecules
  • Different alarm thresholds: CO becomes dangerous at concentrations (50+ PPM) far below what would trigger smoke detection
  • Different response needs: CO poisoning requires different emergency response than a fire

Key Takeaway: A working smoke alarm can save your life in a fire, but it won't protect you from carbon monoxide poisoning. You need both types of detectors for complete home safety.

Types of Fire Detection Systems

Understanding common fire detection technologies helps clarify why they don't detect CO:

1. Ionization Smoke Alarms

  • Contain a small amount of radioactive material
  • Detect invisible combustion particles from flaming fires
  • More responsive to fast, flaming fires

2. Photoelectric Smoke Alarms

  • Use light beams to detect visible smoke particles
  • Better at detecting smoldering, smoky fires
  • Less prone to false alarms from cooking

3. Heat Detectors

  • Respond to temperature changes, not smoke
  • Used in kitchens or garages where smoke alarms would false alarm
  • Completely incapable of detecting any gases

Combination Smoke and CO Detectors

For comprehensive protection, many homeowners choose combination units that include:

  • Both photoelectric smoke detection and CO detection
  • Distinct alarm patterns (usually 3 beeps for smoke, 4 beeps for CO)
  • Voice alerts specifying the danger type
  • Battery backup in hardwired models

Important: Even with combination units, you typically need multiple detectors placed according to both smoke and CO placement guidelines for optimal protection.

Proper Placement for Complete Protection

Detector Type Recommended Locations Installation Height
Smoke Detectors Every bedroom, outside sleeping areas, each level including basement Ceiling or high on wall (6-12" from ceiling)
CO Detectors Near sleeping areas, each habitable level, near attached garage Breathing height (about 5 feet) or per manufacturer

Maintenance Requirements

Both types of detectors require regular maintenance:

  • Monthly testing: Press test button on all detectors
  • Battery replacement: Annually or when low battery chirps
  • Unit replacement: Smoke detectors every 10 years, CO detectors every 5-7 years
  • Cleaning: Vacuum detectors every 6 months to prevent dust buildup
Prev:    Do Carbon Monoxide Detectors Detect Gas Leaks?
Next:    No info
Best-Selling Products
Conventional Smoke Detector
Conventional Smoke Detector
2 wires for the fire alarm 4-wire, network by Relay smoke and heat combo detector available
AJ-K830 Stand Alone Carbon monoxide Detector
AJ-K830 Stand Alone Carbon monoxide Detector
2 years of battery life LCD display EN50291 standard
AJ-965SCU 2-in -1 smoke and carbon monoxide combination detector
AJ-965SCU 2-in -1 smoke and carbon monoxide combination detector
Smoke &CO 2-in-1 10 years of battery life 10 years of CO Sensor EN14604:2005 / EN50291-1:2018...
AJ-833SI-4 Interconencted Carbon monoxide Detector
AJ-833SI-4 Interconencted Carbon monoxide Detector
RF433mhz Wireless Interconnected 10 Years battery lifespan LCD displayer DC6Volt Lithium battery ...
AJ-962TA4 Hardwired Interconnected Heat Alarm
AJ-962TA4 Hardwired Interconnected Heat Alarm
AC220V-AC240V Main powered EN50291 approved RF433mhz Wireless interconnected Compatible with Smok...
AJ-939 ETL Smoke & Carbon Monoxide Alarms
AJ-939 ETL Smoke & Carbon Monoxide Alarms
Smoke and CO 2-in-1 10 years of battery life 10 years of Figaro CO sensor ETL UL217/UL2034 listed...
AJ-965STA4 230V Smoke & Heat alarm
AJ-965STA4 230V Smoke & Heat alarm
Smoke & Heat 2-in-1 10 years of battery life CE EN14604/EN50291/BS5446 listed Low battery war...
AJ-660 WIFI Vape Detector(With Temperature/Humidity)
AJ-660 WIFI Vape Detector(With Temperature/Humidity)
DC5-12V+backup rechargeable lithium battery, TUYA wifi Version, with PM2.5 Sensor Sensors: PM2.5 La...
AJ-765 Wireless Interconnected smoke alarm
AJ-765 Wireless Interconnected smoke alarm
RF433mhz Wireless Interconnected Photoelectric Sensor DC3Volt Lithium battery 10 years of battery...
AJ-773 Lancelot MINI Smoke Alarm
AJ-773 Lancelot MINI Smoke Alarm
Mini Size Smoke Alarm 10 years of battery life Dual tubes Design No false alarm when cooking CE ...
Latest News
Anka Sci-tech logo
Anka Sci-tech Co., Limited established in 2007, is a high-tech enterprise specializing in the whole process of research, development, manufacture and marketing the Fire and home alarm products.
Links 
Product About Us Certificates Video Blog Contact Us Returns&Warranty
Contact us 
Tel:0755 89603006
Phone:13823200453
Email:anka@anka-security.com
Office:602, Floor 6, Building 15, Longbi industrial area, No. 27, Dafa Road, Bantian Street, Longgang District, Shenzhen City, 518129, P.R.China
Factory:2 fl,yangshunmei tech park,Tangkou industrial area, Xinxu town,Huiyang District, Huizhou city, Guangdong province, China.
Verification code
 
WhatsApp Ico Gif
Email Ico Gif
Anka Sci-tech Co., Limited All Rights Reserved    Sitemap